Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Clarke, W. L.
Right arrow Articles by Pohl, S. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Clarke, W. L.
Right arrow Articles by Pohl, S. L.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 10, Issue 5 622-628, Copyright © 1987 by American Diabetes Association


ARTICLES

Evaluating clinical accuracy of systems for self-monitoring of blood glucose

WL Clarke, D Cox, LA Gonder-Frederick, W Carter and SL Pohl
Department of Pediatrics, University of Virginia Medical School, Charlottesville 22908.

Although the scientific literature contains numerous reports of the statistical accuracy of systems for self-monitoring of blood glucose (SMBG), most of these studies determine accuracy in ways that may not be clinically useful. We have developed an error grid analysis (EGA), which describes the clinical accuracy of SMBG systems over the entire range of blood glucose values, taking into account 1) the absolute value of the system-generated glucose value, 2) the absolute value of the reference blood glucose value, 3) the relative difference between these two values, and 4) the clinical significance of this difference. The EGA of accuracy of five different reflectance meters (Eyetone, Dextrometer, Glucometer I, Glucometer II, Memory Glucometer II), a visually interpretable glucose reagent strip (Glucostix), and filter-paper spot glucose determinations is presented. In addition, reanalyses of a laboratory comparison of three reflectance meters (Accucheck II, Glucometer II, Glucoscan 9000) and of two previously published studies comparing the accuracy of five different reflectance meters with EGA is described. EGA provides the practitioner and the researcher with a clinically meaningful method for evaluating the accuracy of blood glucose values generated with various monitoring systems and for analyzing the clinical implications of previously published data.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Diabetes CareHome page
B. Kovatchev, S. Anderson, L. Heinemann, and W. Clarke
Comparison of the Numerical and Clinical Accuracy of Four Continuous Glucose Monitors
Diabetes Care, June 1, 2008; 31(6): 1160 - 1164.
[Abstract] [Full Text] [PDF]


Home page
Diabetes Spectr.Home page
D. K. Bloomgarden, J. Freeman, and E. DeRobertis
Early Patient and Clinician Experiences with Continuous Glucose Monitoring
Diabetes Spectr, April 1, 2008; 21(2): 128 - 133.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
G. J. Worsley, G. A. Tourniaire, K. E. S. Medlock, F. K. Sartain, H. E. Harmer, M. Thatcher, A. M. Horgan, and J. Pritchard
Continuous Blood Glucose Monitoring with a Thin-Film Optical Sensor
Clin. Chem., October 1, 2007; 53(10): 1820 - 1826.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
R. L. Weinstein, S. L. Schwartz, R. L. Brazg, J. R. Bugler, T. A. Peyser, and G. V. McGarraugh
Accuracy of the 5-Day FreeStyle Navigator Continuous Glucose Monitoring System: Comparison with frequent laboratory reference measurements
Diabetes Care, May 1, 2007; 30(5): 1125 - 1130.
[Abstract] [Full Text] [PDF]


Home page
Clin. DiabetesHome page
R. J. Schrot, K. T. Patel, and P. Foulis
Evaluation of Inaccuracies in the Measurement of Glycemia in the Laboratory, by Glucose Meters, and Through Measurement of Hemoglobin A1c
Clin. Diabetes, April 1, 2007; 25(2): 43 - 49.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
S. Garg and L. Jovanovic
Relationship of Fasting and Hourly Blood Glucose Levels to HbA1c Values: Safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor
Diabetes Care, December 1, 2006; 29(12): 2644 - 2649.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
H. G. Piper, J. L. Alexander, A. Shukla, F. Pigula, J. M. Costello, P. C. Laussen, T. Jaksic, and M. S.D. Agus
Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac Surgery
Pediatrics, September 1, 2006; 118(3): 1176 - 1184.
[Abstract] [Full Text] [PDF]


Home page
Am J Health Syst PharmHome page
S. M. Rivers, M. P. Kane, G. Bakst, R. S. Busch, and R. A. Hamilton
Precision and accuracy of two blood glucose meters: FreeStyle Flash versus One Touch Ultra.
Am. J. Health Syst. Pharm., August 1, 2006; 63(15): 1411 - 1416.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
C. De Block, B. Manuel-y-Keenoy, L. Van Gaal, and P. Rogiers
Intensive Insulin Therapy in the Intensive Care Unit: Assessment by continuous glucose monitoring
Diabetes Care, August 1, 2006; 29(8): 1750 - 1756.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
I. M. Wentholt, J. B. Hoekstra, and J. H. DeVries
A Critical Appraisal of the Continuous Glucose-Error Grid Analysis
Diabetes Care, August 1, 2006; 29(8): 1805 - 1811.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
M. Ellmerer, M. Haluzik, J. Blaha, J. Kremen, S. Svacina, W. Toller, J. Mader, L. Schaupp, J. Plank, and T. Pieber
Clinical Evaluation of Alternative-Site Glucose Measurements in Patients After Major Cardiac Surgery.
Diabetes Care, June 1, 2006; 29(6): 1275 - 1281.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
S. Garg, H. Zisser, S. Schwartz, T. Bailey, R. Kaplan, S. Ellis, and L. Jovanovic
Improvement in Glycemic Excursions With a Transcutaneous, Real-Time Continuous Glucose Sensor: A randomized controlled trial
Diabetes Care, January 1, 2006; 29(1): 44 - 50.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
I. M. Wentholt, M. A. Vollebregt, A. A. Hart, J. B. Hoekstra, and J. H. DeVries
Comparison of a Needle-Type and a Microdialysis Continuous Glucose Monitor in Type 1 Diabetic Patients
Diabetes Care, December 1, 2005; 28(12): 2871 - 2876.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
W. L. Clarke, S. Anderson, L. Farhy, M. Breton, L. Gonder-Frederick, D. Cox, and B. Kovatchev
Evaluating the Clinical Accuracy of Two Continuous Glucose Sensors Using Continuous Glucose-Error Grid Analysis
Diabetes Care, October 1, 2005; 28(10): 2412 - 2417.
[Abstract] [Full Text] [PDF]


Home page
Eur J EndocrinolHome page
A. D M Stork, H. Kemperman, D W. Erkelens, and T. F Veneman
Comparison of the accuracy of the hemocue glucose analyzer with the Yellow Springs Instrument glucose oxidase analyzer, particularly in hypoglycemia
Eur. J. Endocrinol., August 1, 2005; 153(2): 275 - 281.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
D. C. Klonoff
Continuous Glucose Monitoring: Roadmap for 21st century diabetes therapy
Diabetes Care, May 1, 2005; 28(5): 1231 - 1239.
[Full Text] [PDF]


Home page
Diabetes CareHome page
N. Lucidarme, C. Alberti, I. Zaccaria, E. Claude, and N. Tubiana-Rufi
Alternate-Site Testing Is Reliable in Children and Adolescents With Type 1 Diabetes, Except at the Forearm for Hypoglycemia Detection
Diabetes Care, March 1, 2005; 28(3): 710 - 711.
[Full Text] [PDF]


Home page
Diabetes CareHome page
G. S. Jeha, L. P. Karaviti, B. Anderson, E. O'Brian Smith, S. Donaldson, T. S. McGirk, and M. W. Haymond
Continuous Glucose Monitoring and the Reality of Metabolic Control in Preschool Children With Type 1 Diabetes
Diabetes Care, December 1, 2004; 27(12): 2881 - 2886.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
B. P. Kovatchev, L. A. Gonder-Frederick, D. J. Cox, and W. L. Clarke
Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors: Continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data
Diabetes Care, August 1, 2004; 27(8): 1922 - 1928.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Sieg, R. H. Guy, and M. B. Delgado-Charro
Noninvasive Glucose Monitoring by Reverse Iontophoresis in Vivo: Application of the Internal Standard Concept
Clin. Chem., August 1, 2004; 50(8): 1383 - 1390.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child.Home page
S Greenhalgh, S Bradshaw, C M Hall, and D A Price
Forearm blood glucose testing in diabetes mellitus
Arch. Dis. Child., June 1, 2004; 89(6): 516 - 518.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
S. K. Garg, S. Schwartz, and S. V. Edelman
Improved Glucose Excursions Using an Implantable Real-Time Continuous Glucose Sensor in Adults With Type 1 Diabetes
Diabetes Care, March 1, 2004; 27(3): 734 - 738.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
F. G.S. Toledo and A. Taylor
Alternative Site Testing at the Earlobe Tip: Reliability of glucose measurements and pain perception
Diabetes Care, February 1, 2004; 27(2): 616 - 617.
[Full Text] [PDF]


Home page
Diabetes CareHome page
D. M. Bina, R. L. Anderson, M. L. Johnson, R. M. Bergenstal, and D. M. Kendall
Clinical Impact of Prandial State, Exercise, and Site Preparation on the Equivalence of Alternative-Site Blood Glucose Testing
Diabetes Care, April 1, 2003; 26(4): 981 - 985.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
P. Bohme, M. Floriot, M.-A. Sirveaux, D. Durain, O. Ziegler, P. Drouin, and B. Guerci
Evolution of Analytical Performance in Portable Glucose Meters in the Last Decade
Diabetes Care, April 1, 2003; 26(4): 1170 - 1175.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
B. Guerci, M. Floriot, P. Bohme, D. Durain, M. Benichou, S. Jellimann, and P. Drouin
Clinical Performance of CGMS in Type 1 Diabetic Patients Treated by Continuous Subcutaneous Insulin Infusion Using Insulin Analogs
Diabetes Care, March 1, 2003; 26(3): 582 - 589.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
M. Metzger, G. Leibowitz, J. Wainstein, B. Glaser, and I. Raz
Response to Mastrototaro and Gross
Diabetes Care, January 1, 2003; 26(1): 256 - 257.
[Full Text] [PDF]


Home page
Diabetes CareHome page
C. D. Malchoff, K. Shoukri, J. I. Landau, and J. M. Buchert
A Novel Noninvasive Blood Glucose Monitor
Diabetes Care, December 1, 2002; 25(12): 2268 - 2275.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
J. M. Ellison, J. M. Stegmann, S. L. Colner, R. H. Michael, M. K. Sharma, K. R. Ervin, and D. L. Horwitz
Rapid Changes in Postprandial Blood Glucose Produce Concentration Differences at Finger, Forearm, and Thigh Sampling Sites
Diabetes Care, June 1, 2002; 25(6): 961 - 964.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. B. Sacks, D. E. Bruns, D. E. Goldstein, N. K. Maclaren, J. M. McDonald, and M. Parrott
Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus
Clin. Chem., March 1, 2002; 48(3): 436 - 472.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
A. Maran, C. Crepaldi, A. Tiengo, G. Grassi, E. Vitali, G. Pagano, S. Bistoni, G. Calabrese, F. Santeusanio, F. Leonetti, et al.
Continuous Subcutaneous Glucose Monitoring in Diabetic Patients: A multicenter analysis
Diabetes Care, February 1, 2002; 25(2): 347 - 352.
[Abstract] [Full Text] [PDF]


Home page
The Diabetes EducatorHome page
D. Lee, S. Weinert, and E. Miler
A Study of Forearm versus Finger Stick: Blood Glucose Monitoring
The Diabetes Educator, November 1, 2001; 27(6_suppl): NP - NP.
[PDF]


Home page
Diabetes CareHome page
S. E. Fineberg, R. M. Bergenstal, R. M. Bernstein, L. M. Laffel, and S. L. Schwartz
Use of an Automated Device for Alternative Site Blood Glucose Monitoring
Diabetes Care, July 1, 2001; 24(7): 1217 - 1220.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. C. Boyd and D. E. Bruns
Quality Specifications for Glucose Meters: Assessment by Simulation Modeling of Errors in Insulin Dose
Clin. Chem., February 1, 2001; 47(2): 209 - 214.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. Mitragotri, M. Coleman, J. Kost, and R. Langer
Analysis of ultrasonically extracted interstitial fluid as a predictor of blood glucose levels
J Appl Physiol, September 1, 2000; 89(3): 961 - 966.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
J. A. Tamada, S. Garg, L. Jovanovic, K. R. Pitzer, S. Fermi, R. O. Potts, and and the Cygnus Research Team
Noninvasive Glucose Monitoring: Comprehensive Clinical Results
JAMA, November 17, 1999; 282(19): 1839 - 1844.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
R. Weitgasser, B. Gappmayer, and M. Pichler
Newer Portable Glucose Meters--Analytical Improvement Compared with Previous Generation Devices?
Clin. Chem., October 1, 1999; 45(10): 1821 - 1825.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
H. A. MacKenzie, H. S. Ashton, S. Spiers, Y. Shen, S. S. Freeborn, J. Hannigan, J. Lindberg, and P. Rae
Advances in Photoacoustic Noninvasive Glucose Testing
Clin. Chem., September 1, 1999; 45(9): 1587 - 1595.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. E. Collison, P. J. Stout, T. S. Glushko, K. N. Pokela, D. J. Mullins-Hirte, J. R. Racchini, M. A. Walter, S. P. Mecca, J. Rundquist, J. J. Allen, et al.
Analytical Characterization of Electrochemical Biosensor Test Strips for Measurement of Glucose in Low-Volume Interstitial Fluid Samples
Clin. Chem., September 1, 1999; 45(9): 1665 - 1673.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Stout, K. Pokela, D. Mullins-Hirte, T. Hoegh, M. Hilgers, A. Thorp, M. Collison, and T. Glushko
Site-to-Site Variation of Glucose in Interstitial Fluid Samples and Correlation to Venous Plasma Glucose
Clin. Chem., September 1, 1999; 45(9): 1674 - 1675.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
O. S. Khalil
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Clin. Chem., February 1, 1999; 45(2): 165 - 177.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
C. Albertson, C. Davis, J. Ellison, and C. Chu
Clinical Evaluation of a New, Miniaturized Biosensor for Self-monitoring of Blood Glucose
Clin. Chem., September 1, 1998; 44(9): 2056 - 2057.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
F. D. Lasky and R. B. Boser
Designing in quality through design control: a manufacturer's perspective
Clin. Chem., May 1, 1997; 43(5): 866 - 872.
[Abstract] [Full Text] [PDF]


Home page
Clin Nurs ResHome page
J. Goff and B. P. Rogers
Selecting a Bedside Glucose Monitor for Outpatient Clinics
Clin Nurs Res, February 1, 1995; 4(1): 105 - 113.
[Abstract] [PDF]


Home page
The Diabetes EducatorHome page
M. A. Bustamante, J. V. Hennessey, M. L. Teter, R. J. Stachler, and B. Warner
Clinical Accuracy of Capillary Blood Glucose Monitoring in Hospitalized Patients with Diabetes
The Diabetes Educator, January 1, 1994; 20(3): 212 - 215.
[PDF]


Home page
The Diabetes EducatorHome page
D. R. Fleming
Accuracy of Blood Glucose Monitoring for Patients: What It Is and How to Achieve It
The Diabetes Educator, January 1, 1994; 20(6): 495 - 500.
[PDF]


Home page
The Diabetes EducatorHome page
D. M. Tomky and D. H. Clarke
A Comparison of User Accuracy, Techniques, and Learning Time of Various Systems for Self Blood Glucose Monitoring
The Diabetes Educator, January 1, 1990; 16(6): 483 - 486.
[PDF]


Home page
The Diabetes EducatorHome page
Beverlyp. Giordano, W. Thrash, L. Hollenbaugh, W. P. Dube, C. Hodges, A. Swain, C. R. Banion, and G. J. Klingensmith
Performance of Seven Blood Glucose Testing Systems at High Altitude
The Diabetes Educator, January 1, 1989; 15(5): 444 - 448.