Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Neuman, R. G.
Right arrow Articles by Braunstein, S. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Neuman, R. G.
Right arrow Articles by Braunstein, S. N.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 13, Issue 10 1069-1073, Copyright © 1990 by American Diabetes Association


ARTICLES

Evaluation of new rapid office test for microalbuminuria and its comparison to fully quantitative radioimmunoassay

RG Neuman, LV Bonomini and SN Braunstein
Exocell, Inc., Philadelphia, PA 19104.

A novel enzyme-linked immunosorbent assay (ELISA [Dialbumin]) for rapid office measurement of microalbuminuria was evaluated and its performance compared with that of a commercially available radioimmunoassay (double-antibody albumin). Urine samples containing between 0.75 and 1800 micrograms/ml of albumin were obtained from 31 diabetic patients and assayed by both methods. A comparison of the paired values obtained from the two methods gave a correlation coefficient of greater than 0.99. The Dialbumin assay, which used detachable eight-well strips (1 strip/sample), 10-min incubation, tap water wash, and a 2-min color development step, was read on both an ELISA reader and a hand-held analytical device (Acc-U-Dial) designed specifically for this test. The findings of this study indicate that the Dialbumin assay, used in conjunction with the Acc-U-Dial device, affords a rapid, convenient, and sensitive method for quantitative determination of a broad range (0.3-1280 micrograms/ml) of urinary albumin levels in the office setting.