Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haardt, M. J.
Right arrow Articles by Bruzzo, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haardt, M. J.
Right arrow Articles by Bruzzo, F.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 17, Issue 8 847-851, Copyright © 1994 by American Diabetes Association


ARTICLES

A cost-benefit comparison of intensive diabetes management with implantable pumps versus multiple subcutaneous injections in patients with type I diabetes

MJ Haardt, JL Selam, G Slama, JP Bethoux, C Dorange, B Mace, ML Ramaniche and F Bruzzo
Department of Diabetology, INSERM Unit 341, Hotel-Dieu Hospital, Paris, France.

OBJECTIVE--To investigate if intraperitoneal (IP) insulin infusion via programmable implantable pumps is a potential alternative to subcutaneous (SC) insulin via multiple injections. RESEARCH DESIGN AND METHODS--We compared the cost-benefits of the two methods using a randomized, prospective, 6-month, crossover design in 10 adult type I diabetic patients. RESULTS--When judged on the last month of IP versus SC periods in the nine patients who completed the study, metabolic data showed better glycemic control (HbA1c: 7.2 +/- 0.2 IP vs. 8.5 +/- 0.7% SC, mean +/- SE, P = 0.02), reduced glycemic fluctuations (SD of capillary glucose values: 3.4 +/- 0.2 IP vs. 4.6 +/- 0.2 mM SC, P < 0.01), and fewer mild hypoglycemic events (5.7 +/- 2.0 IP vs. 10.0 +/- 3.1 events/month SC, P = 0.02). Quality of life, judged by Diabetes Control and Complications Trial questionnaires, was unaffected by pump therapy. Direct costs, including pump acquisition, implantation, and follow-up, were 2.6-fold higher with IP than with SC delivery. CONCLUSIONS--The implantable pump is more effective in the short term, equally accepted, but more costly than multiple injections and should be limited to patients with unsatisfactory glycemic control despite intensive diabetes management with SC insulin. In addition, longer-term, larger-scale, and comparative evaluation is required.