Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Silva, S. R.
Right arrow Articles by Plotnick, L. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Silva, S. R.
Right arrow Articles by Plotnick, L. P.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 19, Issue 1 56-59, Copyright © 1996 by American Diabetes Association


ARTICLES

Can caretakers of children with IDDM accurately measure small insulin doses and dose changes?

SR Silva, L Clark, SN Goodman and LP Plotnick
Johns Hopkins University School of Medicine, Baltimore, MD 21287-3311, USA.

OBJECTIVE: To determine if caretakers of young children with IDDM could consistently reproduce small incremental measurements of insulin (U100). RESEARCH DESIGN AND METHODS: Fifteen caretakers of children with IDDM were asked to deliver repeated small doses of insulin, including doses separated by only 0.25 U of insulin. A sensitive gravimetric technique was used to determine the error in measurement of these low doses of insulin. Statistical analysis was used to evaluate accuracy and internal consistency of each caretaker at each dose. RESULTS: The means +/- SD at each dose level were as follows: 2.75 +/- 0.13 U at 2.5 U, 3.19 +/- 0.13 U at 3.0 U, 3.55 +/- 0.13 U at 3.25 U, and 3.70 +/- 0.11 U at 3.5 U. All doses were biased toward overadministration. There was as statistically significant difference in the dose delivered when the target doses were varied by only 0.25 U. The average differences and standard errors between 2.5 U and 3.0 U, 3.0 U and 3.25 U, and 3.25 U and 3.5 U were 0.44 +/- 0.20 U, 0.36 +/- 0.018 U, and 0.15 +/- 0.017 U, respectively. CONCLUSIONS: Participants were not accurate in measuring small insulin doses, consistently overdrawing insulin by an average of 0.22 U. Caretakers are reasonably internally consistent with a given dose, since participants were able to measure statistically significant differences in 0.25 U dose changes. The error in insulin measurement does not vary with the intended dose level. Caretakers in the same family deliver insulin doses as variable from each other as they are from the population as a whole; however, when two or more individuals are responsible for one insulin dose in a child with IDDM, they have a combined variability that is approximately 40% greater than a single individual's variability.