Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Poirier, J. Y.
Right arrow Articles by Maugendre, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Poirier, J. Y.
Right arrow Articles by Maugendre, D.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 21, Issue 11 1919-1924, Copyright © 1998 by American Diabetes Association


ARTICLES

Clinical and statistical evaluation of self-monitoring blood glucose meters

JY Poirier, N Le Prieur, L Campion, I Guilhem, H Allannic and D Maugendre
Department of Metabolic and Endocrine Diseases, CHU Hopital-Sud, Rennes, France.

OBJECTIVE: Our objective was to compare statistical and clinical methods for the evaluation of five self-monitoring blood glucose (SMBG) meters. RESEARCH DESIGN AND METHODS: Two successive capillary blood glucose measurements were performed, and a simultaneous laboratory venous glucose measurement was used as the reference value. Accuracy was studied by comparing each of the two successive meter values with the reference value by 1) a Spearman's correlation test, 2) a Wilcoxon's paired test, 3) the percentage of values within the 10% interval of the reference value according to the American Diabetes Association consensus statement, and 4) the error grid analysis. RESULTS: The first two methods did not discriminate between the SMBG systems: r was >0.92 for the five meters, and a significant difference between the meter and reference values was found for all but one meter. The two other methods allowed classification of the devices into three groups according to their accuracy: good (two meters), acceptable (two meters), and unacceptable (one meter). These two methods gave consistent results and both had a good reproducibility, because the classification was similar for the two successive measurements. CONCLUSIONS: Both the Spearman's and Wilcoxon's paired tests, although commonly used, are inappropriate to evaluate SMBG systems. The percentage of SMBG values within the +/-10% interval and the error grid analysis are more accurate, because they consistently classified the five glucose meters tested in our study with a high degree of reproducibility.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am J Crit CareHome page
A. Cook, D. Laughlin, M. Moore, D. North, K. Wilkins, G. Wong, A. Wallace-Scroggs, and L. Halvorsen
Differences in Glucose Values Obtained From Point-of-Care Glucose Meters and Laboratory Analysis in Critically Ill Patients
Am. J. Crit. Care., January 1, 2009; 18(1): 65 - 72.
[Abstract] [Full Text] [PDF]


Home page
Ann Clin BiochemHome page
B. Carstensen, J Lindstrom, J Sundvall, K Borch-Johnsen, J Tuomilehto, and the DPS Study Group
Measurement of blood glucose: comparison between different types of specimens
Ann Clin Biochem, March 1, 2008; 45(2): 140 - 148.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
T. Lacara, C. Domagtoy, D. Lickliter, K. Quattrocchi, L. Snipes, J. Kuszaj, and M. Prasnikar
Comparison of Point-of-Care and Laboratory Glucose Analysis in Critically Ill Patients
Am. J. Crit. Care., July 1, 2007; 16(4): 336 - 346.
[Abstract] [Full Text] [PDF]


Home page
Am J Health Syst PharmHome page
S. M. Rivers, M. P. Kane, G. Bakst, R. S. Busch, and R. A. Hamilton
Precision and accuracy of two blood glucose meters: FreeStyle Flash versus One Touch Ultra.
Am. J. Health Syst. Pharm., August 1, 2006; 63(15): 1411 - 1416.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
H T Ho, W K Y Yeung, and B W Y Young
Evaluation of "point of care" devices in the measurement of low blood glucose in neonatal practice
Arch. Dis. Child. Fetal Neonatal Ed., July 1, 2004; 89(4): F356 - F359.
[Abstract] [Full Text] [PDF]


Home page
Journal of Pharmacy PracticeHome page
G. Vincze and A. Parthan
The Value of Home Monitoring Kits in Diabetes, Hypertension, Asthma, and Oral Anticoagulation Therapy
Journal of Pharmacy Practice, June 1, 2004; 17(3): 182 - 196.
[Abstract] [PDF]


Home page
Diabetes CareHome page
P. Bohme, M. Floriot, M.-A. Sirveaux, D. Durain, O. Ziegler, P. Drouin, and B. Guerci
Evolution of Analytical Performance in Portable Glucose Meters in the Last Decade
Diabetes Care, April 1, 2003; 26(4): 1170 - 1175.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
B. Guerci, M. Floriot, P. Bohme, D. Durain, M. Benichou, S. Jellimann, and P. Drouin
Clinical Performance of CGMS in Type 1 Diabetic Patients Treated by Continuous Subcutaneous Insulin Infusion Using Insulin Analogs
Diabetes Care, March 1, 2003; 26(3): 582 - 589.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
J. J. Mastrototaro and T. M. Gross
Reproducibility of the Continuous Glucose Monitoring System Matches Previous Reports and the Intended Use of the Product
Diabetes Care, January 1, 2003; 26(1): 256 - 256.
[Full Text] [PDF]


Home page
The Diabetes EducatorHome page
M. J. Henry, C. A. Major, and S. Reinsch
Accuracy of Self-Monitoring of Blood Glucose: Impact on Diabetes Management Decisions During Pregnancy
The Diabetes Educator, July 1, 2001; 27(4): 521 - 529.
[Abstract] [PDF]


Home page
Diabetes CareHome page
G. Reach
Which Threshold to Detect Hypoglycemia?: Value of receiver-operator curve analysis to find a compromise between sensitivity and specificity
Diabetes Care, May 1, 2001; 24(5): 803 - 804.
[Full Text]


Home page
Clin. Chem.Home page
R. Weitgasser, B. Gappmayer, and M. Pichler
Newer Portable Glucose Meters--Analytical Improvement Compared with Previous Generation Devices?
Clin. Chem., October 1, 1999; 45(10): 1821 - 1825.
[Abstract] [Full Text] [PDF]