Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wing, R. R.
Right arrow Articles by Koeske, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wing, R. R.
Right arrow Articles by Koeske, R.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 8, Issue 5 456-460, Copyright © 1985 by American Diabetes Association


ARTICLES

Compliance to self-monitoring of blood glucose: a marked-item technique compared with self-report

RR Wing, LH Epstein, MP Nowalk, N Scott and R Koeske

This study compared subjects' self-reported rates of compliance to self-monitoring of blood glucose (SMBG) with an objective measure based on a "marked-item" technique. We followed 25 obese patients with type II diabetes who were participating in a behavorial weight control program and monitoring their blood glucose with Chemstrips bG (Bio-Dynamics, Inc., Indianapolis, Indiana). Subjects' self-report significantly overestimated actual compliance as assessed by the marked-item technique. Moreover, the self-report measure failed to identify 35-45% of the noncompliant patients. Compliance decreased steadily over the course of the 37-wk program. Accuracy of SMBG was less problematic than compliance; 85% of patients were able to read Chemstrips bG within 20% of actual blood sugar, and the average blood sugar reading obtained from 2 mo of SMBG correlated highly (r = 0.78, P less than 0.01) with HbA1. Our data suggest that objective measures such as the marked-item technique described in this article should be used to assess compliance to SMBG and behavioral strategies to improve compliance should be developed.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Behav ModifHome page
T. Wysocki
Behavioral Assessment and Intervention in Pediatric Diabetes
Behav Modif, January 1, 2006; 30(1): 72 - 92.
[Abstract] [PDF]


Home page
The Diabetes EducatorHome page
C. E. Golin, M. DIMatteo, B. Leaks, N. Duan, and L. Gelberg
A Diabetes-Specific Measure of Patient Desire to Participate in Medical Decision Making
The Diabetes Educator, November 1, 2001; 27(6): 875 - 886.
[Abstract] [PDF]


Home page
The Diabetes EducatorHome page
S. M.S. Kurtz
Adherence to Diabetes Regimens: Empirical Status and Clinical Applications
The Diabetes Educator, January 1, 1990; 16(1): 50 - 56.
[PDF]


Home page
The Diabetes EducatorHome page
A. M. Delamater, S. G. Davis, J. Bubb, J. V. Santiago, J. A. Smith, and N. H. White
Self-Monitoring of Blood Glucose by Adolescents With Diabetes: Technical Skills and Utilization of Data
The Diabetes Educator, January 1, 1989; 15(1): 56 - 61.
[PDF]


Home page
The Diabetes EducatorHome page
R. W. Sanson-Fisher, E. M. Campbell, S. Redman, and Deborahj. Hennrikus
Patient-Provider Interactions and Patient Outcomes
The Diabetes Educator, January 1, 1989; 15(2): 134 - 138.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 1985 by the American Diabetes Association.