Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Furler, S. M.
Right arrow Articles by Chisholm, D. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Furler, S. M.
Right arrow Articles by Chisholm, D. J.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 8, Issue 6 553-561, Copyright © 1985 by American Diabetes Association


ARTICLES

Blood glucose control by intermittent loop closure in the basal mode: computer simulation studies with a diabetic model

SM Furler, EW Kraegen, RH Smallwood and DJ Chisholm

A semiclosed loop, bedside insulin infusion system using a simple basal infusion algorithm consisting of a linear transition between two insulin delivery rates as blood glucose (BG) increases has been developed. A theoretical study using computer simulation has now been undertaken to examine the effect of BG sampling frequency and algorithm parameters on BG control. A model for BG control by exogenous insulin in the individual with diabetes was developed from a model for healthy subjects and from clinical data in the literature. Results of computer simulation using this model showed a decrease in BG stability as the sampling interval increased from 1 to 4 h. Simulations also showed a decrease in BG stability as the sensitivity of the control algorithm increased. Choice of an appropriate basal control algorithm involved a compromise between stability, sampling interval, and metabolic control. We conclude that satisfactory metabolic control can be obtained using intermittent BG sampling in the basal state; sampling at intervals of 3 h combined with a basal control algorithm whereby insulin delivery rate increases linearly from 0.5 to 2.5 U/h over the BG range 2-12 mmol/L appears suitable for most diabetic persons. Three-hour sampling offers a good compromise between degree of metabolic control and clinical effort involved.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?