Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Berne, C.
Right arrow Articles by Lundgren, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Berne, C.
Right arrow Articles by Lundgren, P.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 9, Issue 1 23-26, Copyright © 1986 by American Diabetes Association


ARTICLES

How accurate are insulin mixtures prepared by the patient?

C Berne, G Eriksson and P Lundgren

The accuracy of mixing two types of insulin in one syringe was studied in 41 insulin-dependent diabetic patients who prepared a mixture of two fluids (saline and sterile water) with either a disposable, 1-ml plastic syringe with a fixed needle, i.e., with a small dead space, or one equipped with a separate needle. Syringes with fixed needles delivered the two components very accurately and were associated with only slight wastage of insulin of 0.011 ml per injection. The syringe with a separate needle delivered 0.033-0.065 ml more than the intended dose of the "first insulin" and correspondingly less of the intended dose of the "second insulin," since the total dose delivered was approximately correct. The magnitude of the insulin wastage of two daily injections was calculated to be 64 ml per patient annually, which could be reduced to 8 ml per patient if fixed needles were used. It is therefore recommended that patients preparing mixtures of two insulins in the same syringe abandon syringes with separate needles.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am J Health Syst PharmHome page
A. J. Erstad, B. L. Erstad, and D. E. Nix
Accuracy and reproducibility of small-volume injections from various-sized syringes
Am. J. Health Syst. Pharm., April 15, 2006; 63(8): 748 - 750.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 1986 by the American Diabetes Association.