Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gifford-Jorgensen, R. A.
Right arrow Articles by Moore, W. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gifford-Jorgensen, R. A.
Right arrow Articles by Moore, W. V.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 9, Issue 1 70-76, Copyright © 1986 by American Diabetes Association


ARTICLES

Comparison of five glucose meters for self-monitoring of blood glucose by diabetic patients

RA Gifford-Jorgensen, J Borchert, R Hassanein, L Tilzer, GA Eaks and WV Moore

This study collected data regarding the accuracy of five currently marketed meters for home use of self-monitoring of blood glucose (SMBG). Data regarding ease of operation of each glucose meter as well as cost and availability of meters and necessary materials were compiled. Fasting blood glucose (BG) samples were drawn from patients in the adult and pediatric diabetes clinics at the University of Kansas College of Health Sciences and Hospital. Specimens were tested by a clinical laboratory as well as by each meter. Unadjusted meter readings of whole BG were plotted against laboratory readings of serum glucose and displayed in scattergrams. Scattergrams showed decreased machine accuracy in upper and lower BG ranges. Whole BG values (meter readings) were adjusted to serum glucose levels by multiplication by 1.12. Adjusted values were compared with laboratory serum values using ANOVA for repeated measures and Dunnett's Multiple Comparisons Test: ANOVA and Dunnett's Multiple Comparisons Test showed only Glucochek II (Medistron, Ltd., West Sussex, England; distributed in U.S. by Larken Industries, Lenexa, Indiana) using Dextrostix reagent strips (Ames Division, Miles Laboratories, Elkhart, Indiana) having a statistically significant difference from laboratory values (P less than 0.01). This meter was recently revised and may show changed accuracy readings. Each meter exhibited inherent advantages and disadvantages regarding price, calibration, strip utilization, and ease of operation, which must be considered before recommendation by the health care provider.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
CLIN PEDIATRHome page
B. Presti, T. Kircher, and C. Reed
Capillary Blood Glucose Monitor: Evaluation in a Newborn Nursery
Clinical Pediatrics, September 1, 1989; 28(9): 412 - 415.
[Abstract] [PDF]


Home page
The Diabetes EducatorHome page
K. Sideman, B. Padilla, T. A. Huff, and M. E. Stachura
Capillary Blood Glucose Monitoring: A Comparison of Two Hospital Quality Control Programs
The Diabetes Educator, January 1, 1988; 14(3): 223 - 226.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 1986 by the American Diabetes Association.