Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shichiri, M.
Right arrow Articles by Abe, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shichiri, M.
Right arrow Articles by Abe, H.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 9, Issue 3 298-301, Copyright © 1986 by American Diabetes Association


ARTICLES

Telemetry glucose monitoring device with needle-type glucose sensor: a useful tool for blood glucose monitoring in diabetic individuals

M Shichiri, N Asakawa, Y Yamasaki, R Kawamori and H Abe

For continuous monitoring of glucose concentration in ambulant diabetic patients, a telemetry glucose monitoring system with a needle-type glucose sensor has been developed. The system consists of a sensor transmitter (4 X 6 X 2 cm, 50 g) that converts current signals generated in a needle-type glucose sensor to high-frequency audio signals and a receiver that continuously calculates glucose concentrations from the received audio signals. The noise range of a monitoring record with the telemetry system (0.3 +/- 0.04%, mean +/- SEM) was significantly smaller than that with a wire-connected system, the wearable artificial endocrine pancreas (2.5 +/- 0.3%). Postprandial tissue glucose concentration responded well to the plasma glucose concentration, with a time lag of 5 min. Continuous glucose monitoring of five diabetic subjects for 77 +/- 22 h revealed that a significant correlation existed between the subcutaneous tissue glucose concentration and the plasma glucose concentration measured simultaneously in each patient. These data indicate the usefulness of the telemetry glucose monitoring system in strict glycemic control of diabetic individuals.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. T. Makale, J. T. Lin, R. E. Calou, A. G. Tsai, P. C. Chen, and D. A. Gough
Tissue window chamber system for validation of implanted oxygen sensors
Am J Physiol Heart Circ Physiol, June 1, 2003; 284(6): H2288 - H2294.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. E. Collison, P. J. Stout, T. S. Glushko, K. N. Pokela, D. J. Mullins-Hirte, J. R. Racchini, M. A. Walter, S. P. Mecca, J. Rundquist, J. J. Allen, et al.
Analytical Characterization of Electrochemical Biosensor Test Strips for Measurement of Glucose in Low-Volume Interstitial Fluid Samples
Clin. Chem., September 1, 1999; 45(9): 1665 - 1673.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 1986 by the American Diabetes Association.