Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Diabetes Care Publish Ahead of Print published online ahead of print December 4, 2007
DOI: 10.2337/dc07-1835

This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
dc07-1835v1
31/3/381    most recent
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Original Research

The relationship of A1c to glucose concentrations in children with type 1 diabetes: Assessments by high frequency glucose determinations by sensors

The Diabetes Research in Children Network (DirecNet) Study Group

ABSTRACT

Objective: Despite its standing as the most validated and widely used measure for average glycemic control over time, the relationship between hemoglobin A1c (A1c) and glucose concentrations is not completely understood. The purpose of this DirecNet study was to utilize continuous glucose monitoring data to examine the relationship between A1c and glucose in type 1 diabetes.

Research Design and Methods: 48 youth enrolled in studies of Navigator continuous glucose monitor were encouraged to wear the Navigator sensor at home continuously. A1c was measured at baseline, 3 months, and 6 months. Sensor glucose data were directly transmitted via the internet, assuring that essentially all glucose values were analyzed.

Results: Subjects had a median of 112 hr/wk of Navigator data in the first 3 months and 115 in the second 3 months. The slope of mean glucose over the previous 3 months vs. A1c was only 18 mg/dL per 1.0% A1c. Individually, there was substantial variation in the relationship between mean glucose and A1c. A1c was not associated with glucose lability after controlling for mean glucose. Measures of an individual's rate of glycation were moderately correlated at the 3 and 6-month visits.

Conclusions: As the chemistry of glycation would predict, we found no evidence to contradict the simple hypothesis that A1c directly reflects the mean glucose over time. There is, however, substantial variability in individual mean glucose concentrations for a given A1c. Transforming reliable A1c values into calculated mean glucose values would, when applied to an individual, introduce substantial error.


Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Diabetes CareHome page
D. M. Nathan, J. Kuenen, R. Borg, H. Zheng, D. Schoenfeld, R. J. Heine, and for the A1c-Derived Average Glucose (ADAG) Study G
Translating the A1C Assay Into Estimated Average Glucose Values
Diabetes Care, August 1, 2008; 31(8): 1473 - 1478.
[Abstract] [Full Text] [PDF]